Setting a Navien controller on a NPE unit
On a Navien NPE series unites there highly efficient condensing ones the controller needs to be set for proper operation. If it just an S2 model you only need to program the date and time, the gas type and altitude because there is no internal pump built into the unit. On the A2 models you will need to program the above plus the circulation method your customer would like.
As far as the factory reset this should only be performed by a licensed plumber trained in Navien Level 3 training.
I have found that the intelligent setting works the best out of all the settings.
If you have a question, please feel free to e mail me at,
economyplmbg@aol.com
I do have a consulting service if you need exten...
Просмотров: 123

Видео

How to install a Navien controller in a sheetrock wall
Просмотров 16214 дней назад
I get quite a few questions on controllers, and I figured let me show you how we install one in a sheetrock wall. Our installs are all about the fit and finish and we like to do 99% of them exactly the same. Surface boxes are all well and good but don't look clean. And if the customer wants to put or push back shelving the external box will be in the way. Like I said in the video sometimes you ...
Flushing a tankless heater on a job.
Просмотров 37321 день назад
I have a lot of flushing videos on tankless heaters, I figured since I had my camera and son in the truck with me, I do a video on a job site. I somehow left my filter removal tool at my studio and did not have one on my truck, so the needle nose pliers will have to do. This site is a 4 tankless install for a RV park bath and laundry house. Just remember flushing is a very important thing to do...
Advanced Navien Training
Просмотров 377Месяц назад
This was part of the three-day course that I was invited to at the Navien training center in New Jersey. The course was the most complete training I ever went to. I drove up from Florida so I could bring my video gear and I could use my own tools and instruments. This video was the steps in removing the different parts and heat exchanger on a Navien NPE unit. I would highly recommend you attend...
Proper piping for multiple Navien tankless heaters, First in Last out
Просмотров 323Месяц назад
I get a lot of questions about this, and I see a lot of improper installations on social media on what a great installation and the hot and cold-water piping is done the wrong way. When you are piping multiple tankless heaters together it is very important to pipe them in as first in last out, if not the unit with the cold water going into it first will do the lion's share of the work. It is al...
Proper condensate drain piping for a condensing tankless heater.
Просмотров 1 тыс.Месяц назад
This is probably one of the most important parts of an installation of a condensing tankless heater. Without proper condensate piping the condensate will back up into the lower heat exchanger and leak out of the seam between the lower and upper exchanger. The example in this video needs to be followed to the letter. One of the first thing a tankless phone Teck will ask to see is the condensate ...
Navien's new NPF 700 Hydro Furnace
Просмотров 7972 месяца назад
This is a new product from Navien, it's like no other air handler on the market. The unit comes with a mini version of their NPE unit. The unit is natural gas but comes with the high altitude and propane conversion kit and the spare parts bag. The unit can mate with a A coil and the return duct can be put on the left side or the right side by cutting open the frame. The unit's condensate, overf...
Changing a Navien water sensor valve
Просмотров 7812 месяца назад
This part is also called a water servo valve, its purpose is to fire up the tankless as water passes through the unit. This is problem the most troublesome problem you will get with a tankless heater. Most of the time it is caused by not flushing the cold-water piping on a new installation or if the water was shut off in the house and debris enters the servo valve. Remember to check the inlet w...
Replacing an internal check valve on a Navien NPE A2 model
Просмотров 2,3 тыс.2 месяца назад
This is a very common problem in areas that have hard water. With any type of check valve buildup inside the piece will cause it to Fowell up. Part# 30024442A Cost $6.95 You can get this piece in the NPE parts service kit. It's very important to check this valve when you do your yearly or Quartey service on your customers unites. It's also important to work the interior/exterior valve. Follow m...
Congo tool expansion tool
Просмотров 3882 месяца назад
Like I said in last week's video there were going to be more tool coming from Congo tool. Most if not all of you know on both of my channels, I always buy my tools to use and review, but I truly believe in this company and both owners. I am very good friends of both of them and their both were in the trade of what I do in my business. This is their expansion or as I and other people call it the...
Proper training on installing tankless heater.
Просмотров 6203 месяца назад
Like I stress in my videos and training you need to properly install a tankless heater.
Training plumbers on how to correctly install a tankless with Navien
Просмотров 1,9 тыс.3 месяца назад
I was asked to help in the training of Navien level 3 training on how to correctly install a Navien tankless heater. This is what I call out of the box training and it pretty much the cause of tankless failures. I have been stressing this training to other tankless companies that have fallen on deaf ears and Navien is the company that would listen. This was what you say as a test, and it went o...
Congo tools new press tool
Просмотров 5253 месяца назад
This is the most affordable pressing tool on the market today. For an 18 Volt platform that can press up to 1 1/4" copper in a compact size is amazing. This was found out after I did this video that the tool will also do up to 1" Mega Press steel piping and fittings. Yes, I will repeat this the tool will do up to 1" Mega Press, so for that price it far exceeds what you're getting for that price...
Naviens new NHW700 noncondensing tankless heater with circulation
Просмотров 5193 месяца назад
This is a game changer for tankless heaters. Now you have three options to install besides the way you can install the NPE unit inside or outside this unit as a U can be installed outside with a hood. the NHW comes in a 160, 180 and a 199 like I said with the U and a hood you can install it outside. You must order the unit either natural gas or propane because its not as easy as the NPE unit to...
Proper condensate drain piping on a Navien tankless.
Просмотров 4,7 тыс.3 месяца назад
I cannot stress how important it is to properly drain the condensate from a tankless heater. The vent is extremely important in the piping to allow the condensate to drain freely. Please follow your local codes on how to neutralize the condensate, but if you need to use the Navien condensate drain kit. Here is a list of the fittings you will need for the near tankless piping, 1/2" CPVC plastic ...
Converting a Navien NPE unit from propane to natural gas
Просмотров 6334 месяца назад
Converting a Navien NPE unit from propane to natural gas
How to remove a stuck or broken Rinnai inlet water filter
Просмотров 1,2 тыс.4 месяца назад
How to remove a stuck or broken Rinnai inlet water filter
Navien 30022965A Navi circ valve
Просмотров 2,2 тыс.5 месяцев назад
Navien 30022965A Navi circ valve
How to remove a filter using the Rinnai filter removal tool.
Просмотров 1,2 тыс.6 месяцев назад
How to remove a filter using the Rinnai filter removal tool.
How to do the descaling on a tankless water heater.
Просмотров 2,1 тыс.6 месяцев назад
How to do the descaling on a tankless water heater.
Holdrite test fitting TRPVC2A
Просмотров 2406 месяцев назад
Holdrite test fitting TRPVC2A
Some of my new tools
Просмотров 3647 месяцев назад
Some of my new tools
I'm back and feeling great.
Просмотров 3877 месяцев назад
I'm back and feeling great.
I'm still alive, had my knee surgery.
Просмотров 56610 месяцев назад
I'm still alive, had my knee surgery.
Navian's common vent collar #30014367A
Просмотров 40210 месяцев назад
Navian's common vent collar #30014367A
Injury to my leg Thats why I've been off YouTube..
Просмотров 614Год назад
Injury to my leg Thats why I've been off RUclips..
Navien's 2-inch common vent collar kit #30014367B
Просмотров 2,3 тыс.Год назад
Navien's 2-inch common vent collar kit #30014367B
Navien's Peak flow series Anti scaling systems
Просмотров 2,1 тыс.Год назад
Navien's Peak flow series Anti scaling systems
Tankless valve kits and which ones to use.
Просмотров 3,4 тыс.Год назад
Tankless valve kits and which ones to use.
March 10, 2023
Просмотров 345Год назад
March 10, 2023

Комментарии

  • @vettetravels
    @vettetravels 9 часов назад

    Hi Mike I think I may have gotten one wire mismatched when reconnecting wires after fan cleaning, everything started when I connected. Hot water ran longer than usual then whole system shut off but not breaker. Im wondering if I can just fix wiring and it will come back on. It is a bit hard to read the wiring diagram on my cover. Do you have any detailed pics of how the wiring colors go? Mine look exactly like your examples, its an RL04

  • @perfectpipesplumbing3992
    @perfectpipesplumbing3992 20 часов назад

    This shouldn't be happening on a brand new install. I just installed three weeks ago and already have a code 12. Now I have a 45 min drive on top of it! UGH!!!!

  • @brock8145
    @brock8145 День назад

    Alot of blah blah blah

  • @BlackRein6
    @BlackRein6 2 дня назад

    Hi Mike, thank you so much for the video!! I think I have just about tried everything for my code 10 and still haven't solved it. So I could use your help! I have a RL75i interior mount with side wall vent (with no other vents or obstructions anywhere nearby) and I have almost always code 10s but have an 11 and 14 in the memory. The unit runs for about 5-10 min then the shower pressure will drop as the hot water stops flowing or it will turn cold. When I am at the unit, the system either appears to start with flame then shut off and restart repeatedly or when it gets cold I see a code 10 with continuous beeping. Thus far I have removed the vent pipe and found dirt dobber nests which I have cleaned, found on on the top of the coil, a gecko and bugs inside the fan which I purchased a new one along with the thermistor which was quite dirty. I pulled the burner and cleaned it with compressed air, blew out the coil from below and back through the air intake from the fan hole. I also replaced the gas manifold, view plate, electrode and flame rods. Almost forgot, I also flushed the system and the water filter was very clean. When I started the burner flame height was low and now is full height. What am I missing here? Please help! Thank you in advance.

  • @superiorcarpetcleaning7972
    @superiorcarpetcleaning7972 3 дня назад

    I just performed my annual flush of my Rannai tankless as I have done in the past. Now when I turn it on, I get a code 11. Research indicates that it is a gas issue. However, the unit has been perfect for 6 years, and I always use the same flush procedures. Is it possible that some are got into the gas line and the unit need to be bled?

  • @yzmoto80
    @yzmoto80 4 дня назад

    Does a twin pipe direct vent on a condensing tankless need a condensate drain incorporated into the vent pipes ? Not asking about the unit, asking about the venting.

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      if you jump up with the 2" pipe you need to have a drain on the bottom with a trap.

  • @peterszalkowski7893
    @peterszalkowski7893 5 дней назад

    Doesn't work what to do??

  • @dbmservicesllc9266
    @dbmservicesllc9266 5 дней назад

    So quick question what did you use to flush the tank cause you did not say nothing on that.

  • @ChrisGenetti
    @ChrisGenetti 6 дней назад

    Hey Mike, I also wanna say thank you I remember paying like seven 800 bucks for someone to clean it out last time with two guys but this time I was able to pop off the front get those three screws off the fan check it. It was true, but there was a bunch of leaves and crap in there so Blew that up put it back blew out the exhaust pipe and we’re good as new. Thank you so much for your help. Appreciate the video. Took me about 15 to 20 minutes from start to finish.

  • @state5stinks880
    @state5stinks880 6 дней назад

    Where can I find the flush kit system at?

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      Any plumbing supply house will have it or Amazon

  • @marvinholmes7925
    @marvinholmes7925 6 дней назад

    Love watching your videos, they are very imformative. Im in the Central Florida area and am currently studying for my license any tips on the best course to take?

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      I run a training class at my studio its either a one- or two-day class given on the weekends. It covers all you would need to know about installing a tankless heater. I cover Navien and Rinnai. e-mail me at economyplmbg@aol.com for details

  • @tommyvacarella1938
    @tommyvacarella1938 6 дней назад

    Phenomenal video. I feel extremely comfortable with taking on this project after seeing this. THANK YOU

  • @yit555
    @yit555 7 дней назад

    Hi, I have a Rinnai R94LS that sounds like an air compressor running when in use. Very loud rumbling/vibrating/humming. It’s intermittent, shows no error codes, and has worked fine for six years. Removed and cleaned out the fan and did not help. What should I check next? Thanks

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      There could be something in the Air box, vent pipe or the high low gas settings are off.

  • @darryllancto709
    @darryllancto709 7 дней назад

    You do amazing videos. Question about the hot recirc line. How to (if possible) deal with the hot water recirc if using a manifold? I have a new RXP199IN being delivered this friday. Thank you in advance.

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      If it's a Viga style manifold like there mana-block the circulation will not work no matter what they tell you. The only fixture that will get hot water the hot line you attach the circulation line too.

  • @martinkoche4375
    @martinkoche4375 8 дней назад

    Very much appreciate your video very informative

  • @KyleRollinsMammothSolutions
    @KyleRollinsMammothSolutions 9 дней назад

    Thanks for pointing out it is capable of being cleaned. That definitely sets it apart for my project which doesn’t use a tankless. I’m bitcoin mining with an immersion tank running a couple heat exchangers for endless hot water while earning bitcoin, and now I want to make it INSTANT as well as endless!

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      I'm glad it helped, question what's Bitcoin mining? I've helped alot of people all over the world but never this lol

  • @DilshatSingh
    @DilshatSingh 11 дней назад

    Dilshad

  • @jessicamann684
    @jessicamann684 11 дней назад

    I get error code 12 on a unit 6 months old. the unit vibrates with a noise a few times then displays error code 12. Any hints if it is something besides the flame senssors?

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      What make and model number

    • @jessicamann684
      @jessicamann684 3 дня назад

      @@ThatTanklessGuy RU199iN I took the front cover off, checked to make sure the screen didn't have debris (or a dead rodent) on it. Checked outsidet to make sure the air inlet isn't covered (with debris or leaves). The PVC only runs about two feet total. the unit worked with the cover off, so I suspect it is an air supply issue, but can't figure out the air supply issue is because nothing is clogged -- unless it is the fan or fan speed control or pressure sensor for the fan. I also know it is NOT the gas supply because I can run the unit at full 200KBTU without any gas supply problems. It seems to be a problem with air supply at lower burner outputs. I put the cover back on and it has been fine for a few days. But I would like this fixed because it has occasionally happened.

  • @tedchapoton977
    @tedchapoton977 11 дней назад

    The further most appliance is the outdoor shower which is supplied with 1/2 copper and is 15 feet from where hot line is 3/4. I was thinking of running my return to farthest point. So if it’s 1/2 does return need be 3/4. You know what that pump flow is so you know best. Thank you for advise

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      It should be all 3/4" a Rinnai will flow through 300 feet at 4.5 and a Navien will flow 600 feet at 5.0

  • @tedchapoton977
    @tedchapoton977 11 дней назад

    Love your channel. We’ve spent so much time watching/learning from you. I’m putting in same return system as you’ve covered in this video including same suggested pump and parts. Can my 60 ft return be 1/2 per or should it be like the main supply and be 3/4? Thank you

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      3/4" is the best, a Rinnai will flow the best with that size pipe

  • @RicheySynthetics
    @RicheySynthetics 13 дней назад

    Awesome tutorial as always, Mike! Thanks for the detailed explanation of all things. Never did list the regulator number. Do you have that or do you suggest an updated version since the making of this video?

  • @matthewfreeland5957
    @matthewfreeland5957 13 дней назад

    Just got mine a few hrs ago . Thanks for the info Great video!

  • @peterfiedler2813
    @peterfiedler2813 13 дней назад

    Absolutely fantastic video! Thank you so much for all the time and effort explaining this set-up. I'm ordering my WiFi system right now for my RL75i.

  • @fluffandfoldmodesto
    @fluffandfoldmodesto 14 дней назад

    Hi I’m following this process with the same tankless unit. My pump is running, service ports open, no fluid being circulated. Any troubleshooting tips?

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      some or the unites you need to power it up first by running a faucet then unplug it. It fakes out the water servo valve.

  • @dalebecker2008
    @dalebecker2008 14 дней назад

    Can you do this with a 240A model also? If so what are the settings?

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      If you talking about an electric tankless no you cant.

  • @ogbinks1661
    @ogbinks1661 15 дней назад

    I 'M WORKING FOR SERVICE COMPAGNY FOR A WILE. and I'M GLAD TO DISCOVER YOUR CHANEL. today I LEARND SOMETHING NEW . it's GOOD TO LEARN FOR BETTER CUSTOMER SERVICE

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      Glad I could help. Look for in the near future I will have training videos on my Patreon page that you can buy and have to learn from.

  • @BreadWinner99
    @BreadWinner99 16 дней назад

    Thank you sir for the guidance. I have to replace one tomorrow 🙏🏽

  • @Brooks.Mechanical.Electric
    @Brooks.Mechanical.Electric 17 дней назад

    Do I need to change the piping to the Navien if I'm using the Navicirc ? I have a customer I installed one for and it still takes 3.5 minutes to get water in the bathroom we put the Navicirc. I have the system set to external recirculation, the valve is set to ext, and the unit is set to always on. Any idea what's going on?

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      !- are the valves fully opened under the sink 2- did you change the Speedy's 3-The Navi-Circ is installed exactly as I show on my video 4- How far away is the fixture 5- Try Inteligent

    • @Brooks.Mechanical.Electric
      @Brooks.Mechanical.Electric 3 дня назад

      @@ThatTanklessGuy yes, I replaced all lav hoses and double checked the stop valves. It's approximately 60' horizontal run and it's a two level house. Navicirc is connected properly. I ran a recirc pump test and confirmed over 2 GPM flow per the digital display.

  • @Scandiaworks
    @Scandiaworks 17 дней назад

    Hey Mike, I have a Rinnai i120S boiler which I installed myself (x general contractor) that is 1 year old which has been working well until recently when there was a power outage. After the power came back on the boiler displays error code 371 (Indirect Tank Thermister ). From the manual's code list, this looks line a faulty thermister. I am only using the boiler to heat the house using radiant heat panels and am not using it for DHW heating. I have not made any changes to the control panel's DIP switches (all set to default OFF positions). The boiler is still heating the panels fine but the front display just keeps flashing the error code on and off in between it's regular display. Could the power surge have damaged the thermister and is displaying the error code because of the damage, even though I do not have an indirect water tank connected? I need to test the condition of the thermister but I don't know where it is located in the boiler. If it is damaged, I would need a part number and where to purchase the replacement. And finally as a note, I now have the boiler plugged into a new UPS which will hopefully give me enough time to run down to the basement and unplug the thing before the USP battery runs out and then the power is restored. Any help would be gratefully appreciated. I love your videos so much! Keep them coming!

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      Did you try jumping out the thermister? Did you happen to take a Ohm reading

  • @judegonzales2231
    @judegonzales2231 17 дней назад

    I see people installing pex for condensation lines on the Navien . This is a big No .

    • @TheBuddylab
      @TheBuddylab 16 дней назад

      I use CPVC ONLY WITH A PLASTIC FEMALE ADAPTOR

  • @judegonzales2231
    @judegonzales2231 17 дней назад

    Shark bite

    • @TheBuddylab
      @TheBuddylab 16 дней назад

      Yes shark bite I’ve been using them since they came out and never had a problem with them.

  • @d66paynter1
    @d66paynter1 17 дней назад

    Hello, Great video can you tell me where to get the the lower enclosure to cover the pipes. The RX199IN is going to be installed on the outside of a brick hose. On lowes web site is picture with it installed but i can seem to find how to purchase. Got the top cap on order as well. Thanks David

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      You can buy it from Rinnai direct or I think Amazon sells it

    • @d66paynter1
      @d66paynter1 3 дня назад

      @@ThatTanklessGuy They referred me to Ferguson got it.

  • @canyonrun2565
    @canyonrun2565 18 дней назад

    Do I need teflon to prevent leaking? Mine leaks even with some teflon

  • @martingargas3217
    @martingargas3217 18 дней назад

    Tilting the vent to drain the condensation outside is a great idea for places in a warmer climate. The manual says tilted back so that the condensate comes inside. I believe the reasoning is that you could build up a giant stalagmite of ice and clog the vent

  • @johnc8369
    @johnc8369 18 дней назад

    Great presentation you was very helpful

  • @mdforseth
    @mdforseth 19 дней назад

    The official Rinnai video says to remove the filter, rinse it clean, then reinstall before de-scaling; then remove, rinse clean, and reinstall again half way through descaling.

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      There wrong you want to have the inlet fully open to get the most solution through the heat exchanger. There is a lot of things Rinnai has on their site that are wrong. Remember there in a lab, I'm in the field lol

  • @PokeBuNz
    @PokeBuNz 21 день назад

    I was under the impression that by cascading the systems via the communication cable the units were able to balance hours used by way of the water adjustment valve. Last year I attended the Navien class in New Jersey and I thought we went over this. This may only be for Naviens, and I may be remembering incorrectly, but I just thought I’d ask why you would need to do FILO in that scenario.

    • @ThatTanklessGuy
      @ThatTanklessGuy 3 дня назад

      Without the correct piping the cascade cables won't work correctly. Only the hours will operate.

  • @DukeJJZ
    @DukeJJZ 21 день назад

    What about piping the condensate drain outside if you live in NYC? Any concern with the water freezing at the end of the pvc that is outside, I only have a a few inches (with an elbow) outside that is already draining my house furnace humidifier.

  • @DukeJJZ
    @DukeJJZ 21 день назад

    When installing the bypass filter in the Y joint, does both O rings go on it? One at the top and the larger one at the bottom?

  • @neiadvv
    @neiadvv 21 день назад

    Question, all time the cold water will be warm ?

  • @DaddyCrossett
    @DaddyCrossett 22 дня назад

    Good stuff. Just did back from Navien to learn about these. Installing in my home next month.

  • @jonnykrivan6840
    @jonnykrivan6840 23 дня назад

    thank you so much this fixed my issue - you are a living legand and are worth your weight in gold!

  • @randyk2941
    @randyk2941 23 дня назад

    I work for a gas company & your videos are SO helpful. Thank you so much!

  • @stevenjohnson626
    @stevenjohnson626 23 дня назад

    Thank you! Very informative

  • @allenemiesforeignanddomest3320
    @allenemiesforeignanddomest3320 24 дня назад

    I have a Rheem and when I run the pump nothing comes out of the hot water side. Is there a trick when you’re powering it down to keep the internal flow valve open?

  • @mykaldenton9384
    @mykaldenton9384 24 дня назад

    Great action information on this tankless flush. Thanks, Mike!

  • @btrent9244
    @btrent9244 24 дня назад

    Excellent in service. Thank you very much.

  • @MrPenguinLife
    @MrPenguinLife 24 дня назад

    Perfect timing for a reminder, I plan to flush my 2 year old Rinnai RL75 heater on Monday

  • @mykaldenton9384
    @mykaldenton9384 24 дня назад

    Greatly appreciate the info. helps make the job easy. Thx Mike!

  • @bosoroni
    @bosoroni 26 дней назад

    Mike - Thank you for this video. I had a pinhole leak in the heat exchanger on a RL94iN and the plumbers quoted me $6400 for a different brand water heater fresh install. Your video gave me the courage to tackle the replacement myself saving a ton of money. Took about 4.5 hours and worked like a charm. Thank you for your knowledge!!!